Wellfleet-FNTS-ATM-MIB device MIB details by Wellfleet
Wellfleet-FNTS-ATM-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing Wellfleet-FNTS-ATM-MIB.
Vendor: | Wellfleet |
---|---|
Mib: | Wellfleet-FNTS-ATM-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
Wellfleet-FNTS-ATM-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Aug 30 16:39:16 EDT 1995 IMPORTS Counter, IpAddress FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 wfFntsAtmGroup FROM Wellfleet-COMMON-MIB; wfFntsAtmTable OBJECT-TYPE SYNTAX SEQUENCE OF WfFntsAtmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Fnts Atm line record" ::= { wfFntsAtmGroup 1 } wfFntsAtmEntry OBJECT-TYPE SYNTAX WfFntsAtmEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the FntsAtm table" INDEX { wfFntsAtmSlot, wfFntsAtmConnector } ::= { wfFntsAtmTable 1 } WfFntsAtmEntry ::= SEQUENCE { wfFntsAtmDelete INTEGER, wfFntsAtmDisable INTEGER, wfFntsAtmState INTEGER, wfFntsAtmSlot INTEGER, wfFntsAtmConnector INTEGER, wfFntsAtmCct INTEGER, wfFntsAtmMtu INTEGER, wfFntsAtmMadr OCTET STRING, wfFntsAtmIpAdr IpAddress, wfFntsAtmAtmState INTEGER, wfFntsAtmSpeed INTEGER, wfFntsAtmRxOctets Counter, wfFntsAtmRxFrames Counter, wfFntsAtmTxOctets Counter, wfFntsAtmTxFrames Counter, wfFntsAtmLackRescErrorRx Counter, wfFntsAtmInErrors Counter, wfFntsAtmOutErrors Counter, wfFntsAtmRxLongFrames Counter, wfFntsAtmTxClipFrames Counter, wfFntsAtmRxReplenMisses Counter, wfFntsAtmRxOverruns Counter, wfFntsAtmRxRingErrors Counter, wfFntsAtmTxRingErrors Counter, wfFntsAtmOpErrors Counter, wfFntsAtmRxProcessings Counter, wfFntsAtmTxProcessings Counter, wfFntsAtmTxCmplProcessings Counter, wfFntsAtmIntrProcessings Counter, wfFntsAtmSintProcessings Counter, wfFntsAtmPintProcessings Counter, wfFntsAtmRxRingLength INTEGER, wfFntsAtmTxRingLength INTEGER, wfFntsAtmCfgRxQueueLength INTEGER, wfFntsAtmCfgTxQueueLength INTEGER, wfFntsAtmLineNumber INTEGER } wfFntsAtmDelete OBJECT-TYPE SYNTAX INTEGER { create(1), delete(2) } ACCESS read-write STATUS mandatory DESCRIPTION "create/delete parameter, dflt = created" DEFVAL { create } ::= { wfFntsAtmEntry 1 } wfFntsAtmDisable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "enable/disable parameter, dflt = enabled" DEFVAL { enable } ::= { wfFntsAtmEntry 2 } wfFntsAtmState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "line driver state variable, Not Present, Init, Down, Up" DEFVAL { notpresent } ::= { wfFntsAtmEntry 3 } wfFntsAtmSlot OBJECT-TYPE SYNTAX INTEGER(1..14) ACCESS read-only STATUS mandatory DESCRIPTION "instance ID Slot, filled in by driver" ::= { wfFntsAtmEntry 4 } wfFntsAtmConnector OBJECT-TYPE SYNTAX INTEGER(1..44) ACCESS read-only STATUS mandatory DESCRIPTION "instance ID Connector, filled in by driver. For the ASN this attribute is an encoded value and is equal to 'module'*10 + 'connector'. Where 'module' is defined in attribute 42 and 'connector' is defined in attribute 43 of this table. For non-ASN platforms this attribute is the physical connector number on the slot." ::= { wfFntsAtmEntry 5 } wfFntsAtmCct OBJECT-TYPE SYNTAX INTEGER(1..1023) ACCESS read-write STATUS mandatory DESCRIPTION "cct number for this line instance" ::= { wfFntsAtmEntry 6 } wfFntsAtmMtu OBJECT-TYPE SYNTAX INTEGER { default(4508) } ACCESS read-write STATUS mandatory DESCRIPTION "mtu parameter, fixed" DEFVAL { default } ::= { wfFntsAtmEntry 7 } wfFntsAtmMadr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "line MAC address, fixed - line driver fills in" ::= { wfFntsAtmEntry 8 } wfFntsAtmIpAdr OBJECT-TYPE SYNTAX IpAddress ACCESS read-only STATUS mandatory DESCRIPTION "Ip Address, for the Sonet RPU" ::= { wfFntsAtmEntry 9 } wfFntsAtmAtmState OBJECT-TYPE SYNTAX INTEGER { notready(1), init(2), intloop(3), extloop(4), reset(5), down(6), up(7), notpresent(9) } ACCESS read-only STATUS mandatory DESCRIPTION "line driver state variable, Not Present, Init, Down, Up" DEFVAL { notpresent } ::= { wfFntsAtmEntry 10 } wfFntsAtmSpeed OBJECT-TYPE SYNTAX INTEGER { default(50) } ACCESS read-only STATUS mandatory DESCRIPTION "Atm Interface speed in Meg bps." DEFVAL { default } ::= { wfFntsAtmEntry 11 } wfFntsAtmRxOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of bytes received from the Atm interface." ::= { wfFntsAtmEntry 12 } wfFntsAtmRxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of frames received from the Atm interface." ::= { wfFntsAtmEntry 13 } wfFntsAtmTxOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of bytes sent to the Atm interface." ::= { wfFntsAtmEntry 14 } wfFntsAtmTxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of frames sent to the Atm interface." ::= { wfFntsAtmEntry 15 } wfFntsAtmLackRescErrorRx OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of requested buffers not available to the driver." ::= { wfFntsAtmEntry 16 } wfFntsAtmInErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of errors on the receive side of the driver." ::= { wfFntsAtmEntry 17 } wfFntsAtmOutErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of errors on the transmit side of the driver." ::= { wfFntsAtmEntry 18 } wfFntsAtmRxLongFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of received frames too long." ::= { wfFntsAtmEntry 19 } wfFntsAtmTxClipFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of transmit frames dropped because of no transmit queue space." ::= { wfFntsAtmEntry 20 } wfFntsAtmRxReplenMisses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of the buffer requests without response." ::= { wfFntsAtmEntry 21 } wfFntsAtmRxOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of receiver overruns." ::= { wfFntsAtmEntry 22 } wfFntsAtmRxRingErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of receiver ring errors." ::= { wfFntsAtmEntry 23 } wfFntsAtmTxRingErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of transmit ring errors." ::= { wfFntsAtmEntry 24 } wfFntsAtmOpErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of operational driver errors." ::= { wfFntsAtmEntry 25 } wfFntsAtmRxProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of times the receive processing has been called." ::= { wfFntsAtmEntry 26 } wfFntsAtmTxProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of times the transmit processing has been called." ::= { wfFntsAtmEntry 27 } wfFntsAtmTxCmplProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of times the transmit complete processing has been called." ::= { wfFntsAtmEntry 28 } wfFntsAtmIntrProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of times the interrupt service routine has been called" ::= { wfFntsAtmEntry 29 } wfFntsAtmSintProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of times the change state interrupt has been called." ::= { wfFntsAtmEntry 30 } wfFntsAtmPintProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "counts the number of times the primitive interrupt service routine has been called." ::= { wfFntsAtmEntry 31 } wfFntsAtmRxRingLength OBJECT-TYPE SYNTAX INTEGER { default(63) } ACCESS read-write STATUS mandatory DESCRIPTION "Atm Interface Receiver Ring Length." DEFVAL { default } ::= { wfFntsAtmEntry 32 } wfFntsAtmTxRingLength OBJECT-TYPE SYNTAX INTEGER { default(63) } ACCESS read-write STATUS mandatory DESCRIPTION "Atm Interface Transmit Ring Length." DEFVAL { default } ::= { wfFntsAtmEntry 33 } wfFntsAtmCfgRxQueueLength OBJECT-TYPE SYNTAX INTEGER { default(127) } ACCESS read-write STATUS mandatory DESCRIPTION "Atm Configurable receive queue length." DEFVAL { default } ::= { wfFntsAtmEntry 34 } wfFntsAtmCfgTxQueueLength OBJECT-TYPE SYNTAX INTEGER { default(127) } ACCESS read-write STATUS mandatory DESCRIPTION "Atm Configurable transmit queue length." DEFVAL { default } ::= { wfFntsAtmEntry 35 } wfFntsAtmLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Unique number identifying this interface." ::= { wfFntsAtmEntry 36 } END -- Wellfleet-FNTS-ATM-MIB