Wellfleet-HSSI-MIB device MIB details by Wellfleet
Wellfleet-HSSI-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing Wellfleet-HSSI-MIB.
Vendor: | Wellfleet |
---|---|
Mib: | Wellfleet-HSSI-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
Wellfleet-HSSI-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Aug 30 16:42:20 EDT 1995 IMPORTS Counter, Gauge, TimeTicks FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 wfLine FROM Wellfleet-COMMON-MIB; wfHssiTable OBJECT-TYPE SYNTAX SEQUENCE OF WfHssiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "HSSI line record" ::= { wfLine 7 } wfHssiEntry OBJECT-TYPE SYNTAX WfHssiEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An entry in the HSSI table" INDEX { wfHssiSlot, wfHssiConnector } ::= { wfHssiTable 1 } WfHssiEntry ::= SEQUENCE { wfHssiDelete INTEGER, wfHssiDisable INTEGER, wfHssiState INTEGER, wfHssiSlot INTEGER, wfHssiConnector INTEGER, wfHssiCct INTEGER, wfHssiBofl INTEGER, wfHssiBoflTmo INTEGER, wfHssiMtu INTEGER, wfHssiMadr OCTET STRING, wfHssiService INTEGER, wfHssiWanProtocol INTEGER, wfHssiTransmissionInterface INTEGER, wfHssiExternalClkSpeed INTEGER, wfHssiCrcSize INTEGER, wfHssiInternalClkTestMode INTEGER, wfHssiRxOctets Counter, wfHssiRxFrames Counter, wfHssiTxOctets Counter, wfHssiTxFrames Counter, wfHssiInDiscards Counter, wfHssiInErrors Counter, wfHssiOutDiscards Counter, wfHssiOutErrors Counter, wfHssiRxLongFrames Counter, wfHssiTxClipFrames Counter, wfHssiRxReplenMisses Counter, wfHssiLastRxErrorCtrl INTEGER, wfHssiRxCrcErrors Counter, wfHssiRxOverruns Counter, wfHssiRxAborts Counter, wfHssiLastTxErrorCtrl INTEGER, wfHssiTxAborts Counter, wfHssiTxUnderruns Counter, wfHssiRxRingErrors Counter, wfHssiLastRxRingState INTEGER, wfHssiRxRingOverruns Counter, wfHssiTxRingErrors Counter, wfHssiLastTxRingState INTEGER, wfHssiPortOpErrors Counter, wfHssiInternOpErrors Counter, wfHssiHostErrors Counter, wfHssiRxProcessings Counter, wfHssiTxProcessings Counter, wfHssiTxCmplProcessings Counter, wfHssiIntrProcessings Counter, wfHssiBoflNum INTEGER, wfHssiBoflLen INTEGER, wfHssiRxBufferLength INTEGER, wfHssiMemPageLength INTEGER, wfHssiRxRingLength INTEGER, wfHssiTxRingLength INTEGER, wfHssiRxFifoWatermark INTEGER, wfHssiTxFifoWatermark INTEGER, wfHssiMaxRxMemory INTEGER, wfHssiLinkInterface INTEGER, wfHssiTurboBofl INTEGER, wfHssiCfgRxQueueLength INTEGER, wfHssiCfgTxQueueLength INTEGER, wfHssiLineNumber INTEGER, wfHssiCfgCngstCtlEnable INTEGER, wfHssiLastChange TimeTicks, wfHssiOutQLen Gauge, wfHssiCarrLossDebounceTmo INTEGER, wfHssiModule INTEGER, wfHssiActualConnector INTEGER, wfHssiLoopback INTEGER, wfHssiReceiveAllFrames INTEGER } wfHssiDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Create/Delete parameter" DEFVAL { created } ::= { wfHssiEntry 1 } wfHssiDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable parameter" DEFVAL { enabled } ::= { wfHssiEntry 2 } wfHssiState OBJECT-TYPE SYNTAX INTEGER { up(1), lmiwait(2), boflwait(3), cawait(4), init(5), notpresent(6), dteloopback(7), dceloopback(8), dceloopbackwait(9), dceloopbacktmo(10), lineloopbofltest(19), notpres(20) } ACCESS read-only STATUS mandatory DESCRIPTION "Line Driver state variable, Not Present, Init, Down, Up" DEFVAL { notpres } ::= { wfHssiEntry 3 } wfHssiSlot OBJECT-TYPE SYNTAX INTEGER(1..14) ACCESS read-only STATUS mandatory DESCRIPTION "Instance ID Slot, filled in by driver" ::= { wfHssiEntry 4 } wfHssiConnector OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Instance ID Connector, filled in by driver" ::= { wfHssiEntry 5 } wfHssiCct OBJECT-TYPE SYNTAX INTEGER(1..1023) ACCESS read-write STATUS mandatory DESCRIPTION "CCT number for this line instance" ::= { wfHssiEntry 6 } wfHssiBofl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "breath of life parameter" DEFVAL { enabled } ::= { wfHssiEntry 7 } wfHssiBoflTmo OBJECT-TYPE SYNTAX INTEGER(1..60) ACCESS read-write STATUS mandatory DESCRIPTION "breath of life frequency in seconds" DEFVAL { 1 } ::= { wfHssiEntry 8 } wfHssiMtu OBJECT-TYPE SYNTAX INTEGER(3..4608) ACCESS read-write STATUS mandatory DESCRIPTION "MTU parameter, this is buffer size for HSSI media, fixed" DEFVAL { 4608 } ::= { wfHssiEntry 9 } wfHssiMadr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "Line MAC address, fixed - line driver fills in from the 48 bit address stored in the serial number prom for this connector." ::= { wfHssiEntry 10 } wfHssiService OBJECT-TYPE SYNTAX INTEGER { transparent(1), undefined(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Service type for this circuit. Transparent is raw HDLC mode, and is the only service provided on the current HSSI product" DEFVAL { transparent } ::= { wfHssiEntry 11 } wfHssiWanProtocol OBJECT-TYPE SYNTAX INTEGER { standard(1), passthru(2), ppp(3), smds(4), framerelay(5), atm(6), sw(7), switch(8) } ACCESS read-write STATUS mandatory DESCRIPTION "WAN protocol selection is provided via this parameter. The supported protocols can be selected per interface." DEFVAL { standard } ::= { wfHssiEntry 12 } wfHssiTransmissionInterface OBJECT-TYPE SYNTAX INTEGER { dsone(1), dsthree(3) } ACCESS read-write STATUS mandatory DESCRIPTION "T1 or T3, in the future OC1, OC3 and OC12. Used for MIB selection" DEFVAL { dsthree } ::= { wfHssiEntry 13 } wfHssiExternalClkSpeed OBJECT-TYPE SYNTAX INTEGER(307200..52638515) ACCESS read-write STATUS mandatory DESCRIPTION "External Clock Speed, Used in the future for route selection" DEFVAL { 46359642 } ::= { wfHssiEntry 14 } wfHssiCrcSize OBJECT-TYPE SYNTAX INTEGER { crc16bit(1), crc32bit(2) } ACCESS read-write STATUS mandatory DESCRIPTION "CRC size parameter, 16 bit standard CCITT or extended 32 bit CRC" DEFVAL { crc32bit } ::= { wfHssiEntry 15 } wfHssiInternalClkTestMode OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enables internal transmit clock generation. Should NEVER be enabled for normal operation." DEFVAL { disabled } ::= { wfHssiEntry 16 } wfHssiRxOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes received without error" ::= { wfHssiEntry 17 } wfHssiRxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received without error" ::= { wfHssiEntry 18 } wfHssiTxOctets OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of bytes transmitted without error" ::= { wfHssiEntry 19 } wfHssiTxFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames transmitted without error" ::= { wfHssiEntry 20 } wfHssiInDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of error-free inbound packets discarded. Usually due to lack of memory resources." ::= { wfHssiEntry 21 } wfHssiInErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of inbound packets not delivered to higher-layer protocol because of errors." ::= { wfHssiEntry 22 } wfHssiOutDiscards OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of error-free outbound packets discarded. Usually due to lack of transmission bandwidth." ::= { wfHssiEntry 23 } wfHssiOutErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of outbound packets that could not be transmitted because of errors." ::= { wfHssiEntry 24 } wfHssiRxLongFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Long frames dropped on receive because of length" ::= { wfHssiEntry 25 } wfHssiTxClipFrames OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames clipped in the transmit routine" ::= { wfHssiEntry 26 } wfHssiRxReplenMisses OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of failed attempts by the line driver to aquire a packet buffer" ::= { wfHssiEntry 27 } wfHssiLastRxErrorCtrl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last errored receive descriptor's control field" ::= { wfHssiEntry 28 } wfHssiRxCrcErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with CRC errors" ::= { wfHssiEntry 29 } wfHssiRxOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with fifo overrun errors" ::= { wfHssiEntry 30 } wfHssiRxAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received with abort status" ::= { wfHssiEntry 31 } wfHssiLastTxErrorCtrl OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last errored transmit descriptor's control field" ::= { wfHssiEntry 32 } wfHssiTxAborts OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of transmit frames with internal abort errors" ::= { wfHssiEntry 33 } wfHssiTxUnderruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of transmit frames aborted with underrun errors" ::= { wfHssiEntry 34 } wfHssiRxRingErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of receive ring error events" ::= { wfHssiEntry 35 } wfHssiLastRxRingState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last 8 bit value from the recv ring state register" ::= { wfHssiEntry 36 } wfHssiRxRingOverruns OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of receive ring overrun events" ::= { wfHssiEntry 37 } wfHssiTxRingErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of transmit ring error events" ::= { wfHssiEntry 38 } wfHssiLastTxRingState OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Last 8 bit value from the transmit ring state register" ::= { wfHssiEntry 39 } wfHssiPortOpErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of port operation error events" ::= { wfHssiEntry 40 } wfHssiInternOpErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of internal operation error events" ::= { wfHssiEntry 41 } wfHssiHostErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of parity errs on host accesses to directly accessable registers." ::= { wfHssiEntry 42 } wfHssiRxProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of receive frame processings (RINT)" ::= { wfHssiEntry 43 } wfHssiTxProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of transmit processings, invokations of transmit routine" ::= { wfHssiEntry 44 } wfHssiTxCmplProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of transmit complete processings (TINT)" ::= { wfHssiEntry 45 } wfHssiIntrProcessings OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Interrupt processings, invokations of intr routine" ::= { wfHssiEntry 46 } wfHssiBoflNum OBJECT-TYPE SYNTAX INTEGER(1..127) ACCESS read-write STATUS mandatory DESCRIPTION "Number of breath of life packets per breath of life" DEFVAL { 5 } ::= { wfHssiEntry 47 } wfHssiBoflLen OBJECT-TYPE SYNTAX INTEGER(22..4450) ACCESS read-write STATUS mandatory DESCRIPTION "breath of life packet length" DEFVAL { 100 } ::= { wfHssiEntry 48 } wfHssiRxBufferLength OBJECT-TYPE SYNTAX INTEGER { length4k(64), length8k(128) } ACCESS read-write STATUS mandatory DESCRIPTION "Performance tunning parameter controls Receive buffer size." DEFVAL { length4k } ::= { wfHssiEntry 49 } wfHssiMemPageLength OBJECT-TYPE SYNTAX INTEGER { length32(1), length256(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Performance tunning parameter controls device memory access burst length." DEFVAL { length32 } ::= { wfHssiEntry 50 } wfHssiRxRingLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Receive Queue Length." ::= { wfHssiEntry 51 } wfHssiTxRingLength OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current Transmit Queue Length." ::= { wfHssiEntry 52 } wfHssiRxFifoWatermark OBJECT-TYPE SYNTAX INTEGER(2..255) ACCESS read-write STATUS mandatory DESCRIPTION "Performance tunning parameter controls the receive watermark." DEFVAL { 2 } ::= { wfHssiEntry 53 } wfHssiTxFifoWatermark OBJECT-TYPE SYNTAX INTEGER(2..255) ACCESS read-write STATUS mandatory DESCRIPTION "Performance tunning parameter controls the transmit watermark." DEFVAL { 16 } ::= { wfHssiEntry 54 } wfHssiMaxRxMemory OBJECT-TYPE SYNTAX INTEGER(1..255) ACCESS read-write STATUS mandatory DESCRIPTION "Performance tunning parameter controls fifo area allowed for receive." DEFVAL { 1 } ::= { wfHssiEntry 55 } wfHssiLinkInterface OBJECT-TYPE SYNTAX INTEGER { default(1), ace25(2), ace32(3) } ACCESS read-write STATUS mandatory DESCRIPTION "Only for DEBUG." DEFVAL { default } ::= { wfHssiEntry 56 } wfHssiTurboBofl OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Only for DEBUG, Turbo breath of life parameter" DEFVAL { disabled } ::= { wfHssiEntry 57 } wfHssiCfgRxQueueLength OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Configured Receive Queue Length. Values other than zero over-ride the router selected values. A value of zero has a special meaning. Zero causes router based default values to be used. Values larger than the compiled ring size are truncated to the compiled ring size. " ::= { wfHssiEntry 58 } wfHssiCfgTxQueueLength OBJECT-TYPE SYNTAX INTEGER(0..255) ACCESS read-write STATUS mandatory DESCRIPTION "Configured Transmit Queue Length. Values other than zero over-ride the router selected values. A value of zero has a special meaning. Zero causes router based default values to be used. Values larger than the compiled ring size are truncated to the compiled ring size. " ::= { wfHssiEntry 59 } wfHssiLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "line number for this line instance" ::= { wfHssiEntry 60 } wfHssiCfgCngstCtlEnable OBJECT-TYPE SYNTAX INTEGER { enable(1), disable(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Configured Congestion Control Enable. Enable or disable BNX switch congestion control on this HSSI port. Note that this has relevance only in the BNX switch and (currently) Frame Relay and SMDS switching functionality. If enabled, congestion control will monitor the levels of traffic and congestion and mark and drop certain packets as per of Frame Relay or SMDS protocols. See BNX doc for details on the congestion control strategy." DEFVAL { disable } ::= { wfHssiEntry 61 } wfHssiLastChange OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "The value of SysUpTime at the time the interface entered it's current operational state (UP state). SysUpTime is defined as the time (in hundredths of a second) since the network management portion of the system was last re-initialized. Usually the time since boot." ::= { wfHssiEntry 62 } wfHssiOutQLen OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "The instantaneous current length of the output packet queue (in packets)." ::= { wfHssiEntry 63 } wfHssiCarrLossDebounceTmo OBJECT-TYPE SYNTAX INTEGER(0..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute determines how many seconds to wait before transitioning to the Carrier Lost state when the Carrier Signal is lost. When set to 0 (default), the Driver will immediately transition to the lost state upon detecting Carrier Loss. If the Carrier Signal returns prior to reaching this threshold, the Driver will not enter the Carrier Lost state at all." DEFVAL { 0 } ::= { wfHssiEntry 64 } wfHssiModule OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4) } ACCESS read-only STATUS mandatory DESCRIPTION "Module number for ASN platform, filled in by driver. For non-ASN platforms this attribute will not be used." ::= { wfHssiEntry 65 } wfHssiActualConnector OBJECT-TYPE SYNTAX INTEGER { one(1), two(2), three(3), four(4), five(5), six(6), seven(7), eight(8) } ACCESS read-only STATUS mandatory DESCRIPTION "Actual connector number for ASN platform, filled in by driver. For non-ASN platforms, this attribute will not be used." ::= { wfHssiEntry 66 } wfHssiLoopback OBJECT-TYPE SYNTAX INTEGER { none(1), localdigital(2), localline(3), remoteline(4) } ACCESS read-write STATUS mandatory DESCRIPTION "Loopback type requested, Local Digital (Loop A), Local Line (Loop B), Remote Line (Loop C), or none" DEFVAL { none } ::= { wfHssiEntry 67 } wfHssiReceiveAllFrames OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute enables delivery of all receive frames to the HSSI device driver for processing. When disabled, frames less than 4 bytes in length are filtered out of the receive frame stream before reaching the device driver. It is necessary to enable the attribute when running Frame Relay switched virtual circuits (SVC) in order to allow the reception of 3 byte frames." DEFVAL { disabled } ::= { wfHssiEntry 68 } END -- Wellfleet-HSSI-MIB