Wellfleet-STATS-MIB device MIB details by Wellfleet
Wellfleet-STATS-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing Wellfleet-STATS-MIB.
Vendor: | Wellfleet |
---|---|
Mib: | Wellfleet-STATS-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
Wellfleet-STATS-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Aug 30 16:48:24 EDT 1995 IMPORTS Gauge FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 DisplayString FROM RFC1213-MIB wfStatsDcGroup FROM Wellfleet-COMMON-MIB; wfStatsDc OBJECT IDENTIFIER ::= { wfStatsDcGroup 1 } wfStatsDcDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable Statistical Data Collection." DEFVAL { disabled } ::= { wfStatsDc 1 } wfStatsDcVolume OBJECT-TYPE SYNTAX INTEGER(0..14) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the file system volume number to which the Statistical Data Collection info files will be written. The volume number corresponds to the slot number on which the volume resides. " DEFVAL { 4 } ::= { wfStatsDc 2 } wfStatsDcFilePrefix OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The name of statistical data files." ::= { wfStatsDc 3 } wfStatsDcUpdateInterval OBJECT-TYPE SYNTAX INTEGER(10..2147483647) ACCESS read-write STATUS obsolete DESCRIPTION "This number specifies the interval (number of minutes) for the STATS process to collect and update STATS data." DEFVAL { 60 } ::= { wfStatsDc 4 } wfStatsDcStoreInterval OBJECT-TYPE SYNTAX INTEGER(10..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This number specifies the interval (number of minutes) for the STATS master process to collect and update STATS data from each slot and to write statistical data on to the file system. " DEFVAL { 60 } ::= { wfStatsDc 5 } wfStatsDcUpdateData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS obsolete DESCRIPTION "Setting this attribute to a non-zero value will cause an immediate updating of the statistical data. Once activated, this attribute should be reset to zero to allow subsequent activations. " ::= { wfStatsDc 6 } wfStatsDcStoreData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute to a non-zero value will cause an immediate writing of the statistical data info to a file in SRAM. Once activated, this attribute should be reset to zero to allow subsequent activations. " ::= { wfStatsDc 7 } wfStatsDcSwitchId OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "switch id used in the statistical data file to identify BNX. If it is not given explicitely, it will be assigned with wfSysName." ::= { wfStatsDc 8 } wfStatsDcEnableAll OBJECT-TYPE SYNTAX INTEGER { on(1), off(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute, if set, will overwrite individual logical line enable/disable setting of statistical data collection." DEFVAL { off } ::= { wfStatsDc 9 } wfStatsDcMaxNumFiles OBJECT-TYPE SYNTAX INTEGER(0..144) ACCESS read-write STATUS mandatory DESCRIPTION "This attribute sets the MAX number of STATS files in an SRAM. If this number is reached, before writing the next STATS DC file to SRAM, the older STATS DC file will be delete. Note: Value 0 has the special meaning that this limitation will not take into effect. The DC file will be written in the round robin manner." ::= { wfStatsDc 10 } wfStatsDcFrVcDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this switch is turned on, the stats data of all VCs of the configured circuit will be collected. This is per BNX." DEFVAL { disabled } ::= { wfStatsDc 11 } wfStatsDcState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "current state." DEFVAL { notpresent } ::= { wfStatsDc 12 } wfStatsDcHssiFields OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "************************************************************" DEFVAL { 4278190080 } ::= { wfStatsDc 13 } wfStatsDcSyncFields OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "************************************************************" DEFVAL { 4278190080 } ::= { wfStatsDc 14 } wfStatsDcDs1E1Fields OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "************************************************************" DEFVAL { 4294836224 } ::= { wfStatsDc 15 } wfStatsDcFrSwVcFields OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "************************************************************" DEFVAL { 4294966272 } ::= { wfStatsDc 16 } wfStatsDcCctCngcFields OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "************************************************************" DEFVAL { 4294901760 } ::= { wfStatsDc 17 } wfStatsDcFddiFields OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "************************************************************" ::= { wfStatsDc 18 } wfStatsDcCctCngcDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "This attribute is to enable.disable frsw cngc data collection" DEFVAL { disabled } ::= { wfStatsDc 19 } wfStatsDcLbcFileDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To enable/disable LBC file write." DEFVAL { disabled } ::= { wfStatsDc 20 } wfStatsDcAtmzPhyFields OBJECT-TYPE SYNTAX Gauge ACCESS read-write STATUS mandatory DESCRIPTION "Selection of Atmz Line Attributes for Data Collection " DEFVAL { 4294967264 } ::= { wfStatsDc 21 } wfStatsDcMediaTable OBJECT-TYPE SYNTAX SEQUENCE OF WfStatsDcMediaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "STATS Generic Media table for Generic media drivers using Line Number in their mib." ::= { wfStatsDcGroup 2 } wfStatsDcMediaEntry OBJECT-TYPE SYNTAX WfStatsDcMediaEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters for Stats." INDEX { wfStatsDcMediaLineNumber } ::= { wfStatsDcMediaTable 1 } WfStatsDcMediaEntry ::= SEQUENCE { wfStatsDcMediaDelete INTEGER, wfStatsDcMediaLineNumber INTEGER } wfStatsDcMediaDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indicates status of this entry." DEFVAL { created } ::= { wfStatsDcMediaEntry 1 } wfStatsDcMediaLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Instance identifier; this indicates which line number NOTE: Line number is based on the following scheme: msb 0 00 00 00 0 00 lsb resv. chan type slot mod conn" ::= { wfStatsDcMediaEntry 2 } wfStatsDcLbcTable OBJECT-TYPE SYNTAX SEQUENCE OF WfStatsDcLbcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "LBC Entry using line number as its index." ::= { wfStatsDcGroup 3 } wfStatsDcLbcEntry OBJECT-TYPE SYNTAX WfStatsDcLbcEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "LBC Entry using line number as its index." INDEX { wfStatsDcLbcLineNumber } ::= { wfStatsDcLbcTable 1 } WfStatsDcLbcEntry ::= SEQUENCE { wfStatsDcLbcDelete INTEGER, wfStatsDcLbcDisable INTEGER, wfStatsDcLbcLineNumber INTEGER, wfStatsDcLbcUpdateInterval INTEGER, wfStatsDcLbcState INTEGER, wfStatsDcLbcRxMaxDelta0 Gauge, wfStatsDcLbcTxMaxDelta0 Gauge, wfStatsDcLbcRxMaxDelta1 Gauge, wfStatsDcLbcTxMaxDelta1 Gauge, wfStatsDcLbcRxMaxDelta2 Gauge, wfStatsDcLbcTxMaxDelta2 Gauge, wfStatsDcLbcRxMaxDelta3 Gauge, wfStatsDcLbcTxMaxDelta3 Gauge, wfStatsDcLbcRxMaxDelta4 Gauge, wfStatsDcLbcTxMaxDelta4 Gauge, wfStatsDcLbcRxMaxDelta5 Gauge, wfStatsDcLbcTxMaxDelta5 Gauge, wfStatsDcLbcRxMaxDelta6 Gauge, wfStatsDcLbcTxMaxDelta6 Gauge, wfStatsDcLbcRxMaxDelta7 Gauge, wfStatsDcLbcTxMaxDelta7 Gauge, wfStatsDcLbcRxMaxDelta8 Gauge, wfStatsDcLbcTxMaxDelta8 Gauge, wfStatsDcLbcRxMaxDelta9 Gauge, wfStatsDcLbcTxMaxDelta9 Gauge, wfStatsDcLbcRxMaxDelta10 Gauge, wfStatsDcLbcTxMaxDelta10 Gauge, wfStatsDcLbcRxMaxDelta11 Gauge, wfStatsDcLbcTxMaxDelta11 Gauge, wfStatsDcLbcRxMaxDelta12 Gauge, wfStatsDcLbcTxMaxDelta12 Gauge, wfStatsDcLbcRxMaxDelta13 Gauge, wfStatsDcLbcTxMaxDelta13 Gauge, wfStatsDcLbcRxMaxDelta14 Gauge, wfStatsDcLbcTxMaxDelta14 Gauge, wfStatsDcLbcRxMaxDelta15 Gauge, wfStatsDcLbcTxMaxDelta15 Gauge, wfStatsDcLbcRxMaxDelta16 Gauge, wfStatsDcLbcTxMaxDelta16 Gauge, wfStatsDcLbcRxMaxDelta17 Gauge, wfStatsDcLbcTxMaxDelta17 Gauge, wfStatsDcLbcRxMaxDelta18 Gauge, wfStatsDcLbcTxMaxDelta18 Gauge, wfStatsDcLbcRxMaxDelta19 Gauge, wfStatsDcLbcTxMaxDelta19 Gauge, wfStatsDcLbcRxMaxDelta20 Gauge, wfStatsDcLbcTxMaxDelta20 Gauge, wfStatsDcLbcRxMaxDelta21 Gauge, wfStatsDcLbcTxMaxDelta21 Gauge, wfStatsDcLbcRxMaxDelta22 Gauge, wfStatsDcLbcTxMaxDelta22 Gauge, wfStatsDcLbcRxMaxDelta23 Gauge, wfStatsDcLbcTxMaxDelta23 Gauge } wfStatsDcLbcDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "To create or delete this instance." DEFVAL { created } ::= { wfStatsDcLbcEntry 1 } wfStatsDcLbcDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "When this switch is turned on, BNX will read the configured trunk line's rx/tx counter value at a predetermined time frequency." DEFVAL { enabled } ::= { wfStatsDcLbcEntry 2 } wfStatsDcLbcLineNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "line number for this line instance" ::= { wfStatsDcLbcEntry 3 } wfStatsDcLbcUpdateInterval OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "The value must be divisible into 60. In another word, 60/value must be an integer." DEFVAL { 5 } ::= { wfStatsDcLbcEntry 4 } wfStatsDcLbcState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "TBC state " DEFVAL { notpresent } ::= { wfStatsDcLbcEntry 5} wfStatsDcLbcRxMaxDelta0 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 0." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 6 } wfStatsDcLbcTxMaxDelta0 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 0." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 7 } wfStatsDcLbcRxMaxDelta1 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 1." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 8 } wfStatsDcLbcTxMaxDelta1 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 1." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 9 } wfStatsDcLbcRxMaxDelta2 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 2." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 10 } wfStatsDcLbcTxMaxDelta2 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 2." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 11 } wfStatsDcLbcRxMaxDelta3 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 3." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 12 } wfStatsDcLbcTxMaxDelta3 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 3." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 13 } wfStatsDcLbcRxMaxDelta4 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 4." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 14 } wfStatsDcLbcTxMaxDelta4 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 4." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 15 } wfStatsDcLbcRxMaxDelta5 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 5." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 16 } wfStatsDcLbcTxMaxDelta5 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 5." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 17 } wfStatsDcLbcRxMaxDelta6 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 6." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 18 } wfStatsDcLbcTxMaxDelta6 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 6." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 19 } wfStatsDcLbcRxMaxDelta7 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 7." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 20 } wfStatsDcLbcTxMaxDelta7 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 7." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 21 } wfStatsDcLbcRxMaxDelta8 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 8." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 22 } wfStatsDcLbcTxMaxDelta8 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 8." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 23 } wfStatsDcLbcRxMaxDelta9 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 9." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 24 } wfStatsDcLbcTxMaxDelta9 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 9." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 25 } wfStatsDcLbcRxMaxDelta10 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 10." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 26 } wfStatsDcLbcTxMaxDelta10 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 10." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 27 } wfStatsDcLbcRxMaxDelta11 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 11." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 28 } wfStatsDcLbcTxMaxDelta11 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 11." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 29 } wfStatsDcLbcRxMaxDelta12 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 12." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 30 } wfStatsDcLbcTxMaxDelta12 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 12." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 31 } wfStatsDcLbcRxMaxDelta13 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 13." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 32 } wfStatsDcLbcTxMaxDelta13 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 13." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 33 } wfStatsDcLbcRxMaxDelta14 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 14." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 34 } wfStatsDcLbcTxMaxDelta14 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 14." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 35 } wfStatsDcLbcRxMaxDelta15 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 15." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 36 } wfStatsDcLbcTxMaxDelta15 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 15." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 37 } wfStatsDcLbcRxMaxDelta16 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 16." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 38 } wfStatsDcLbcTxMaxDelta16 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 16." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 39 } wfStatsDcLbcRxMaxDelta17 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 17." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 40 } wfStatsDcLbcTxMaxDelta17 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 17." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 41 } wfStatsDcLbcRxMaxDelta18 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 18." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 42 } wfStatsDcLbcTxMaxDelta18 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 18." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 43 } wfStatsDcLbcRxMaxDelta19 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 19." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 44 } wfStatsDcLbcTxMaxDelta19 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 19." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 45 } wfStatsDcLbcRxMaxDelta20 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 20." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 46 } wfStatsDcLbcTxMaxDelta20 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 20." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 47 } wfStatsDcLbcRxMaxDelta21 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 21." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 48 } wfStatsDcLbcTxMaxDelta21 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 21." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 49 } wfStatsDcLbcRxMaxDelta22 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 22." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 50 } wfStatsDcLbcTxMaxDelta22 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 22." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 51 } wfStatsDcLbcRxMaxDelta23 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the rx bytes count for this instance in hour 23." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 52 } wfStatsDcLbcTxMaxDelta23 OBJECT-TYPE SYNTAX Gauge ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of the tx bytes count for this instance in hour 23." DEFVAL { 0 } ::= { wfStatsDcLbcEntry 53 } END -- Wellfleet-STATS-MIB