Wellfleet-SWSMDS-MIB device MIB details by Wellfleet
Wellfleet-SWSMDS-MIB file content
The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.
Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.
Use ActiveXperts Network Monitor 2024 to import vendor-specific MIB files, inclusing Wellfleet-SWSMDS-MIB.
Vendor: | Wellfleet |
---|---|
Mib: | Wellfleet-SWSMDS-MIB [download] [view objects] |
Tool: | ActiveXperts Network Monitor 2024 [download] (ships with advanced SNMP/MIB tools) |
Wellfleet-SWSMDS-MIB DEFINITIONS ::= BEGIN -- Created by mdl2asn version 3.1 -- Creation date: Wed Aug 30 16:48:30 EDT 1995 IMPORTS IpAddress, Counter, Gauge, TimeTicks, Opaque, enterprises, mgmt FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212 TRAP-TYPE FROM RFC-1215 DisplayString, mib-2 FROM RFC1213-MIB wfSmdsSwGroup FROM Wellfleet-COMMON-MIB; wfSmdsSwSubTable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwSubEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Wellfleet SMDS Switch Circuit (SNI, subscriber) Record. This record holds information on a per circuit (SSI, SNI, subscriber) basis." ::= { wfSmdsSwGroup 1 } wfSmdsSwSubEntry OBJECT-TYPE SYNTAX WfSmdsSwSubEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Per Wellfleet circuit SMDS Switch configuration parameters and counters. This table contains Subscriber-Network Interface (SNI) parameters and state variables, one entry per SIP port." INDEX { wfSmdsSwSubCct } ::= { wfSmdsSwSubTable 1 } WfSmdsSwSubEntry ::= SEQUENCE { wfSmdsSwSubDelete INTEGER, wfSmdsSwSubDisable INTEGER, wfSmdsSwSubState INTEGER, wfSmdsSwSubCct INTEGER, wfSmdsSwSubDisableHrtbtPoll INTEGER, wfSmdsSwSubHrtbtPollAddr INTEGER, wfSmdsSwSubHrtbtPollInterval INTEGER, wfSmdsSwSubHrtbtPollDownCount INTEGER, wfSmdsSwSubDisableNetMgmt INTEGER, wfSmdsSwSubInterfaceType INTEGER, wfSmdsSwSubInterfaceIndex INTEGER, wfSmdsSwSubDisableL3PduChecks INTEGER, wfSmdsSwSubDisableUsageGeneration INTEGER, wfSmdsSwSubDisableMIR INTEGER, wfSmdsSwSubUnassignedSAs Counter, wfSmdsSwSubSAScreenViolations Counter, wfSmdsSwSubDAScreenViolations Counter, wfSmdsSwSubNumPDUExceededMIR Counter, wfSmdsSwSubSipL3ReceivedIAs Counter, wfSmdsSwSubSipL3ReceivedGAs Counter, wfSmdsSwSubSipL3UnrecIAs Counter, wfSmdsSwSubSipL3UnrecGAs Counter, wfSmdsSwSubSipL3SentIAs Counter, wfSmdsSwSubSipL3SentGAs Counter, wfSmdsSwSubSipL3Errors Counter, wfSmdsSwSubSipL3InvAddrTypes Counter, wfSmdsSwSubSipL3VersionSupport INTEGER, wfSmdsSwSubSAScrnViolationOccur OCTET STRING, wfSmdsSwSubDAScrnViolationOccur OCTET STRING, wfSmdsSwSubUnassignedSAOccur OCTET STRING, wfSmdsSwSubSAErrorOccur OCTET STRING, wfSmdsSwSubDAErrorOccur OCTET STRING, wfSmdsSwSubInvalidBASizeOccur OCTET STRING, wfSmdsSwSubInvalidHELenOccur OCTET STRING, wfSmdsSwSubInvalidHEVerOccur OCTET STRING, wfSmdsSwSubInvalidHECarOccur OCTET STRING, wfSmdsSwSubInvalidHEPadOccur OCTET STRING, wfSmdsSwSubBEtagOccur OCTET STRING, wfSmdsSwSubBAsizeNELenOccur OCTET STRING, wfSmdsSwSubIncorrectLenOccur OCTET STRING, wfSmdsSwSubExceededMIROccur OCTET STRING, wfSmdsSwSubInBandMgmtDisable INTEGER, wfSmdsSwSubInBandMgmtLocalAddr OCTET STRING, wfSmdsSwSubInBandMgmtReceivedPDUs Counter, wfSmdsSwSubInBandMgmtSentPDUs Counter, wfSmdsSwSubInBandMgmtMaxLenErrors Counter, wfSmdsSwSubInBandMgmtEncapsErrors Counter, wfSmdsSwSubGAPartialResolve Counter, wfSmdsSwSubDANotOnSni Counter } wfSmdsSwSubDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "create/delete parameter, dflt = created" DEFVAL { created } ::= { wfSmdsSwSubEntry 1 } wfSmdsSwSubDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "enable/disable parameter, dflt = enabled" DEFVAL { enabled } ::= { wfSmdsSwSubEntry 2 } wfSmdsSwSubState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "SMDS Switch state variable, Up, Down Init, Not Present" DEFVAL { notpresent } ::= { wfSmdsSwSubEntry 3 } wfSmdsSwSubCct OBJECT-TYPE SYNTAX INTEGER(1..1023) ACCESS read-only STATUS mandatory DESCRIPTION "cct number for this instance" ::= { wfSmdsSwSubEntry 4 } wfSmdsSwSubDisableHrtbtPoll OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "determine use of DXI heartbeat poll" DEFVAL { disabled } ::= { wfSmdsSwSubEntry 5 } wfSmdsSwSubHrtbtPollAddr OBJECT-TYPE SYNTAX INTEGER { cpe(1), net(2) } ACCESS read-write STATUS mandatory DESCRIPTION "determine if heartbeat poll messages are sent as as CPE or network (CSU/DSU) messages." DEFVAL { net } ::= { wfSmdsSwSubEntry 6 } wfSmdsSwSubHrtbtPollInterval OBJECT-TYPE SYNTAX INTEGER(6..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "heartbeat polling messages get sent every this many seconds - we don't want the polling interval to be less than or equal to the no-acknowledgment timer." DEFVAL { 10 } ::= { wfSmdsSwSubEntry 7 } wfSmdsSwSubHrtbtPollDownCount OBJECT-TYPE SYNTAX INTEGER(1..10) ACCESS read-write STATUS mandatory DESCRIPTION "if this many consecutive heartbeat polling messages go unacknowledged, log an event declaring the line down" DEFVAL { 3 } ::= { wfSmdsSwSubEntry 8 } wfSmdsSwSubDisableNetMgmt OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "determine use of LMI network management" DEFVAL { disabled } ::= { wfSmdsSwSubEntry 9 } wfSmdsSwSubInterfaceType OBJECT-TYPE SYNTAX INTEGER { sni(1), ssi(2) } ACCESS read-write STATUS mandatory DESCRIPTION "defines whether this interface is a SNI or SSI." DEFVAL { sni } ::= { wfSmdsSwSubEntry 10 } wfSmdsSwSubInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The index number for the SSI/SNI. Each SNI in the network has a unique id. The value of this object identifies the SIP port interface for which this entry contains management information." ::= { wfSmdsSwSubEntry 11 } wfSmdsSwSubDisableL3PduChecks OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable L3_PDU verification. Default is disabled." DEFVAL { enabled } ::= { wfSmdsSwSubEntry 12 } wfSmdsSwSubDisableUsageGeneration OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "enable/disable usage data generation. Default is disabled." DEFVAL { disabled } ::= { wfSmdsSwSubEntry 13 } wfSmdsSwSubDisableMIR OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "enable/disable MIR enforcement, default is disabled." DEFVAL { disabled } ::= { wfSmdsSwSubEntry 14 } wfSmdsSwSubUnassignedSAs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SIP Level 3 PDUs discarded by the SMDS Switch because the Source Address was not assigned to the SNI." ::= { wfSmdsSwSubEntry 15 } wfSmdsSwSubSAScreenViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of SIP L3_PDUs that violated the address screen based on source address screening for an SNI." ::= { wfSmdsSwSubEntry 16 } wfSmdsSwSubDAScreenViolations OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SIP Level 3 PDUs that violated the Destination Address Screening using either an Individual Address Screen or a Group Address Screen for the SNI." ::= { wfSmdsSwSubEntry 17 } wfSmdsSwSubNumPDUExceededMIR OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SIP L3_PDUs that exceeded the MIR on this interface." ::= { wfSmdsSwSubEntry 18 } wfSmdsSwSubSipL3ReceivedIAs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of individually addressed SIP Level 3 PDUs received by the SMDS Switch from the CPE. The total includes only unerrored L3PDUs." ::= { wfSmdsSwSubEntry 19 } wfSmdsSwSubSipL3ReceivedGAs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of group addressed SIP Level 3 PDUs received by the SMDS Switch from the CPE. The total includes only unerrored L3PDUs." ::= { wfSmdsSwSubEntry 20 } wfSmdsSwSubSipL3UnrecIAs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of SIP Level 3 PDUs received by the SMDS Switch from the CPE that have an unknown, valid, individual SMDS Destination Address." ::= { wfSmdsSwSubEntry 21 } wfSmdsSwSubSipL3UnrecGAs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of SIP Level 3 PDUs received by the SMDS Switch from the CPE that have an unknown, valid, group SMDS Destination Address." ::= { wfSmdsSwSubEntry 22 } wfSmdsSwSubSipL3SentIAs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of individually addressed SIP Level 3 PDUs that have been sent by this SMDS Switch to the CPE." ::= { wfSmdsSwSubEntry 23 } wfSmdsSwSubSipL3SentGAs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of group addressed SIP L3PDUs that have been sent by this SMDS Switch to the CPE." ::= { wfSmdsSwSubEntry 24 } wfSmdsSwSubSipL3Errors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SIP Level 3 PDUs received by the SMDS Switch from the CPE that were discovered to have protocol errors." ::= { wfSmdsSwSubEntry 25 } wfSmdsSwSubSipL3InvAddrTypes OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of SIP Level 3 PDUs received by the SMDS Switch from the CPE that had a value in the Source or Destination Address type subfield other than group or individual. Or if the Source Address type subfield value indicates a group address." ::= { wfSmdsSwSubEntry 26 } wfSmdsSwSubSipL3VersionSupport OBJECT-TYPE SYNTAX INTEGER { version(1) } ACCESS read-only STATUS mandatory DESCRIPTION "A value which indicates the version(s) of SIP that this SNI supports. The value is a sum. This sum initially takes the value zero. For each version, V, that this interface supports, 2 raised to (V - 1) is added to the sum. For example, a port supporting versions 1 and 2 would have a value of (2^(1-1)+2^(2-1))=3. The SipL3VersionSupport is effectively a bit mask with Version 1 equal to the least significant bit (LSB)." DEFVAL { version } ::= { wfSmdsSwSubEntry 27 } wfSmdsSwSubSAScrnViolationOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded as a result of a Source Address violation." ::= { wfSmdsSwSubEntry 28 } wfSmdsSwSubDAScrnViolationOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded as a result of a Destination Address violation." ::= { wfSmdsSwSubEntry 29 } wfSmdsSwSubUnassignedSAOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded as a result of a unassigned Source Address." ::= { wfSmdsSwSubEntry 30 } wfSmdsSwSubSAErrorOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of a Source Address Field Format error." ::= { wfSmdsSwSubEntry 31 } wfSmdsSwSubDAErrorOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of a Destination Address Field Format error." ::= { wfSmdsSwSubEntry 32 } wfSmdsSwSubInvalidBASizeOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid BASize field value." ::= { wfSmdsSwSubEntry 33 } wfSmdsSwSubInvalidHELenOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid Header Extension Length Field value." ::= { wfSmdsSwSubEntry 34 } wfSmdsSwSubInvalidHEVerOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid Header Extension Version element." ::= { wfSmdsSwSubEntry 35 } wfSmdsSwSubInvalidHECarOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid Header Extension Carrier element." ::= { wfSmdsSwSubEntry 36 } wfSmdsSwSubInvalidHEPadOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an invalid Header Extension Pad element." ::= { wfSmdsSwSubEntry 37 } wfSmdsSwSubBEtagOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of a Beginning-End Tag mismatch." ::= { wfSmdsSwSubEntry 38 } wfSmdsSwSubBAsizeNELenOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because the BAsize and Length fields are not equal." ::= { wfSmdsSwSubEntry 39 } wfSmdsSwSubIncorrectLenOccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because of an incorrect length." ::= { wfSmdsSwSubEntry 40 } wfSmdsSwSubExceededMIROccur OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "A string containing the SMDS Source Address, Destination Address, and Event time of the most recent occurance of an L3_PDU discarded because it exceeded the MIR." ::= { wfSmdsSwSubEntry 41 } wfSmdsSwSubInBandMgmtDisable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "In-Band Management enable/disable parameter. This attribute indicates whether the local WSNI (only) is enabled to run IP in Host mode, for in-band management purposes, in additional to being a switch interface. The default is disabled" DEFVAL { disabled } ::= { wfSmdsSwSubEntry 42 } wfSmdsSwSubInBandMgmtLocalAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-write STATUS mandatory DESCRIPTION "Special SMDS E.164 Individual address that identifies this local circuit. This attribute is only used when the wfSmdsSwSubInBandMgmtDisable attribute is set to ENABLED" ::= { wfSmdsSwSubEntry 43 } wfSmdsSwSubInBandMgmtReceivedPDUs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The total number of individually addressed In-Band Management PDUs received by the SMDS Switch from the CPE. The total includes only unerrored PDUs." ::= { wfSmdsSwSubEntry 44 } wfSmdsSwSubInBandMgmtSentPDUs OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of individually addressed In-Band Management PDUs that have been sent by this SMDS Switch to the CPE." ::= { wfSmdsSwSubEntry 45 } wfSmdsSwSubInBandMgmtMaxLenErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of In-Band Management PDUs that have exceeded the MTU size configured for the line" ::= { wfSmdsSwSubEntry 46 } wfSmdsSwSubInBandMgmtEncapsErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of In-Band Management PDUs that have invalid encapsulation schemes" ::= { wfSmdsSwSubEntry 47 } wfSmdsSwSubGAPartialResolve OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times group addressed L3_PDU's could not be resolved due to congestion." ::= { wfSmdsSwSubEntry 48 } wfSmdsSwSubDANotOnSni OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "The number of times a L3_PDU was discarded at the egress because the destination address was not assigned to the SNI." ::= { wfSmdsSwSubEntry 49 } wfSmdsSwEndpTable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwEndpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Parameters for the Endpoint table. An Endpoint is defined as an IP address, SMDS E.164 address pair. Endpoint ranges should never overlap." ::= { wfSmdsSwGroup 2 } wfSmdsSwEndpEntry OBJECT-TYPE SYNTAX WfSmdsSwEndpEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters for a particular Endpoint." INDEX { wfSmdsSwEndpE164AddrHigh, wfSmdsSwEndpE164AddrDelta, wfSmdsSwEndpInterfaceIndex } ::= { wfSmdsSwEndpTable 1 } WfSmdsSwEndpEntry ::= SEQUENCE { wfSmdsSwEndpDelete INTEGER, wfSmdsSwEndpE164AddrHigh OCTET STRING, wfSmdsSwEndpE164AddrDelta OCTET STRING, wfSmdsSwEndpInterfaceIndex INTEGER } wfSmdsSwEndpDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indication to delete this endpoint entry." DEFVAL { created } ::= { wfSmdsSwEndpEntry 1 } wfSmdsSwEndpE164AddrHigh OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "The High end of the E.164 address range for this endpoint information." ::= { wfSmdsSwEndpEntry 2 } wfSmdsSwEndpE164AddrDelta OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "The difference between wfSmdsSwEndpE164AddrHigh to the beginning of the endpoint information." ::= { wfSmdsSwEndpEntry 3 } wfSmdsSwEndpInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This number indicates which SNI the endpoint information refers to." ::= { wfSmdsSwEndpEntry 4 } wfSmdsSwInterfaceTable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This is the Interface Table. This table also holds the Maximum Information Rate (MIR) information." ::= { wfSmdsSwGroup 3 } wfSmdsSwInterfaceEntry OBJECT-TYPE SYNTAX WfSmdsSwInterfaceEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table defines the IP addresses and what interfaces they are associated with." INDEX { wfSmdsSwInterfaceType, wfSmdsSwInterfaceIndex } ::= { wfSmdsSwInterfaceTable 1 } WfSmdsSwInterfaceEntry ::= SEQUENCE { wfSmdsSwInterfaceDelete INTEGER, wfSmdsSwInterfaceType INTEGER, wfSmdsSwInterfaceIndex INTEGER, wfSmdsSwInterfaceIpAddr IpAddress, wfSmdsSwInterfaceMIR INTEGER, wfSmdsSwInterfaceCurrentRate INTEGER } wfSmdsSwInterfaceDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indication to delete this interface entry." DEFVAL { created } ::= { wfSmdsSwInterfaceEntry 1 } wfSmdsSwInterfaceType OBJECT-TYPE SYNTAX INTEGER { sni(1), ssi(2) } ACCESS read-only STATUS mandatory DESCRIPTION "This number determines whether the interface information refers to an SNI, SSI, or ICI." ::= { wfSmdsSwInterfaceEntry 2 } wfSmdsSwInterfaceIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This number indicates which SNI, SSI, or ICI the interface information refers to." ::= { wfSmdsSwInterfaceEntry 3 } wfSmdsSwInterfaceIpAddr OBJECT-TYPE SYNTAX IpAddress ACCESS read-write STATUS mandatory DESCRIPTION "IP Address associated with the interface." ::= { wfSmdsSwInterfaceEntry 4 } wfSmdsSwInterfaceMIR OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This number represents the MIR in octets per second." ::= { wfSmdsSwInterfaceEntry 5 } wfSmdsSwInterfaceCurrentRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This number indicates the current rate of traffic flow to the interface. The software updates this counter. When this attribute exceeds wfSmdsSwInterfaceMIR traffic to the interface is dropped. Periodically the sofware resets this counter to zero." ::= { wfSmdsSwInterfaceEntry 6 } wfSmdsSwAssocScrnTable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwAssocScrnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list identifies the associated SNI addresses per individualand group address screen. Different addresses on an SNI may be associated with different individual and group address screens (one individual address screen per associated address on an SNI, and one group address screen per associated address on an SNI )." ::= { wfSmdsSwGroup 4 } wfSmdsSwAssocScrnEntry OBJECT-TYPE SYNTAX WfSmdsSwAssocScrnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An SNI index, group and individual screening list index, and the associated addresses for the SNI for the address screens." INDEX { wfSmdsSwAssocScrnSniIndex, wfSmdsSwAssocScrnAddrInd, wfSmdsSwAssocScrnIndivIndex, wfSmdsSwAssocScrnGrpIndex } ::= { wfSmdsSwAssocScrnTable 1 } WfSmdsSwAssocScrnEntry ::= SEQUENCE { wfSmdsSwAssocScrnDelete INTEGER, wfSmdsSwAssocScrnSniIndex INTEGER, wfSmdsSwAssocScrnAddrInd OCTET STRING, wfSmdsSwAssocScrnIndivIndex INTEGER, wfSmdsSwAssocScrnGrpIndex INTEGER } wfSmdsSwAssocScrnDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indication to delete this associated screen entry." DEFVAL { created } ::= { wfSmdsSwAssocScrnEntry 1 } wfSmdsSwAssocScrnSniIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the SIP Port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex, defined in RFC1213, for the same interface." ::= { wfSmdsSwAssocScrnEntry 2 } wfSmdsSwAssocScrnAddrInd OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies one of the SMDS addresses for the SNI, identified by the wfSmdsSwAssocScrnSniIndex that belongs to this individual (or group) address screen (wfSmdsSwAssocScrnAddrInd). This list will contain both individual and group addresses, because this list is used for both Destination Address Screening and Source Address Screening; the destination address in the L3_PDU that is undergoing Source Address Screening may be either a group or individual address that is assigned to that SNI. One screen will have a maximum of 64 associated addresses; up to a maximum of 16 individual addresses identifying an SNI and up to a maximum of 48 group addresses identifying an SNI." ::= { wfSmdsSwAssocScrnEntry 3 } wfSmdsSwAssocScrnIndivIndex OBJECT-TYPE SYNTAX INTEGER(1..4) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the individual address screening list. There is at least one individual address screen and at most s individual address screens per SNI. The initial value of s is defined to be 4. In the future more screening lists per SNI may be allowed. The values of this object correspond to the values of wfSmdsSwIAScrnIndex in the wfSmdsSwIAScrnTable." ::= { wfSmdsSwAssocScrnEntry 4 } wfSmdsSwAssocScrnGrpIndex OBJECT-TYPE SYNTAX INTEGER(1..4) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the group address screening list. There is at least one group address screen and at most s group address screens per SNI. The initial value of s is defined to be 4. In the future more screening lists per SNI may be allowed. The values of this object correspond to the values of wfSmdsSwGAScrnIndex in the wfSmdsSwGAScrnTable. This field applies only to individual addresses on the SNI because it applies only to destination address screening of group addresses." ::= { wfSmdsSwAssocScrnEntry 5 } wfSmdsSwIAScrnTable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwIAScrnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list identifies the individual addresses that will be screened per individual address screen table. The are up to s (s is equal to 4) individual address screens per SNI and at least one individual address screen per SNI. The Individual Address Screens and the Group Address Screens together consist of up to n addresses. The initial value of n is defined as 128. In the future a value of n up to 2048 may be supported. The Individual Address Screen is used to perform Destination Address Screening for individually addressed data units and Source Address Screening for all data units. The Group Address Screen is used to perform Destination Address Screening for group addressed data units." ::= { wfSmdsSwGroup 5 } wfSmdsSwIAScrnEntry OBJECT-TYPE SYNTAX WfSmdsSwIAScrnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An SNI index, a screening list index, the individual addresses to be screened for the individual address screen, and whether the screened address is valid or invalid." INDEX { wfSmdsSwIAScrnSniIndex, wfSmdsSwIAScrnIndex, wfSmdsSwIAScrnAddr } ::= { wfSmdsSwIAScrnTable 1 } WfSmdsSwIAScrnEntry ::= SEQUENCE { wfSmdsSwIAScrnDelete INTEGER, wfSmdsSwIAScrnSniIndex INTEGER, wfSmdsSwIAScrnIndex INTEGER, wfSmdsSwIAScrnAddr OCTET STRING } wfSmdsSwIAScrnDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indication to delete this IA screen entry." DEFVAL { created } ::= { wfSmdsSwIAScrnEntry 1 } wfSmdsSwIAScrnSniIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the SIP Port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex, defined in RFC1213, for the same interface." ::= { wfSmdsSwIAScrnEntry 2 } wfSmdsSwIAScrnIndex OBJECT-TYPE SYNTAX INTEGER(1..4) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the individual address screening list. There are at least one individual address screen and at most s individual address screens per SNI. The initial value of s is defined to be 4. In the future more screening lists per SNI may be allowed. The values of this object correspond to the values of wfSmdsSwScrnIndex in the wfSmdsSwScrnTable." ::= { wfSmdsSwIAScrnEntry 3 } wfSmdsSwIAScrnAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies one of the individual addresses to be screened for source and destination address screening for the SNI identified by the wfSmdsSwIAScrnSniIndex and for the particular individual address screen (wfSmdsSwIAScrnIndex)." ::= { wfSmdsSwIAScrnEntry 4 } wfSmdsSwGAScrnTable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwGAScrnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This list identifies the group addresses that will be screened per group address screen table. The are up to s (s is equal to 4) group address screens per SNI and at least one group address screen per SNI. The Individual Address Screen and the Group Address Screen together consist of up to n addresses. The initial value of n is defined as 128. In the future a value of n up to 2048 may be supported. The Individual Address Screen is used to perform Destination Address Screening for individually addressed data units and Source Address Screening for all data units. The Group Address Screen is used to perform Destination Address Screening for group addressed data units." ::= { wfSmdsSwGroup 6 } wfSmdsSwGAScrnEntry OBJECT-TYPE SYNTAX WfSmdsSwGAScrnEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "An SNI index, a screening list index, the group addresses to be screened for the group address screen, and whether the screened address is valid or invalid." INDEX { wfSmdsSwGAScrnSniIndex, wfSmdsSwGAScrnIndex, wfSmdsSwGAScrnAddr } ::= { wfSmdsSwGAScrnTable 1 } WfSmdsSwGAScrnEntry ::= SEQUENCE { wfSmdsSwGAScrnDelete INTEGER, wfSmdsSwGAScrnSniIndex INTEGER, wfSmdsSwGAScrnIndex INTEGER, wfSmdsSwGAScrnAddr OCTET STRING } wfSmdsSwGAScrnDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indication to delete this GA screen entry." DEFVAL { created } ::= { wfSmdsSwGAScrnEntry 1 } wfSmdsSwGAScrnSniIndex OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the SIP Port interface for which this entry contains management information. The value of this object for a particular interface has the same value as the ifIndex, defined in RFC1213, for the same interface." ::= { wfSmdsSwGAScrnEntry 2 } wfSmdsSwGAScrnIndex OBJECT-TYPE SYNTAX INTEGER(1..4) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies the group address screening list. There is at least one group address screen and at most s group address screens per SNI. The initial value of s is defined to be 4. In the future more screening lists per SNI may be allowed. The values of this object correspond to the values of wfSmdsSwScrnIndex in the wfSmdsSwSmdsScrnTable." ::= { wfSmdsSwGAScrnEntry 3 } wfSmdsSwGAScrnAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "The value of this object identifies one of the group addresses to be screened for destination address screening for the SNI identified by the wfSmdsSwGAScrnSniIndex and for the particular group address screen (wfSmdsSwGAScrnIndex)." ::= { wfSmdsSwGAScrnEntry 4 } wfSmdsSwGATable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwGAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A table of all group addresses in the network and the associated individual addresses identified by each group address. A group address identifies up to m individual addresses. An SMDS SS supports up to n group addresses. A group address can be identified by up to p individual addresses. A particular SNI is identified by up to 48 group addresses. The initial values of m, n, and p are defined as 128, 1024, and 32, respectively. In the future values of m and n of 2048 and 8192, respectively, may be supported." ::= { wfSmdsSwGroup 7 } wfSmdsSwGAEntry OBJECT-TYPE SYNTAX WfSmdsSwGAEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A Group Address and an address in that group and whether that association is valid or invalid." INDEX { wfSmdsSwGASSI, wfSmdsSwGAGroupAddress, wfSmdsSwGAGroupMember } ::= { wfSmdsSwGATable 1 } WfSmdsSwGAEntry ::= SEQUENCE { wfSmdsSwGADelete INTEGER, wfSmdsSwGASSI INTEGER, wfSmdsSwGAGroupAddress OCTET STRING, wfSmdsSwGAGroupMember OCTET STRING } wfSmdsSwGADelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indication to delete this group address entry." DEFVAL { created } ::= { wfSmdsSwGAEntry 1 } wfSmdsSwGASSI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The SSI associated with this Group Address. An SSI of 0 is used to indicate that all interfaces can use the group address. An SSI other than 0 indicates that only the SSI, or an SNI associated with the SSI should use the group." ::= { wfSmdsSwGAEntry 2 } wfSmdsSwGAGroupAddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "A Group Address." ::= { wfSmdsSwGAEntry 3 } wfSmdsSwGAGroupMember OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "An individual SMDS address that belongs to this Group Address." ::= { wfSmdsSwGAEntry 4 } wfSmdsSwCurUsageTable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwCurUsageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains the Current Usage Data. This is the interface between Billing and Switching. The Switch gates create these records. The Billing gates collect them to create billing data." ::= { wfSmdsSwGroup 8 } wfSmdsSwCurUsageEntry OBJECT-TYPE SYNTAX WfSmdsSwCurUsageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The usage data for the current usage period indexed by destination,source address." INDEX { wfSmdsSwCurUsageSni, wfSmdsSwCurUsageDestAddr, wfSmdsSwCurUsageSrcAddr } ::= { wfSmdsSwCurUsageTable 1 } WfSmdsSwCurUsageEntry ::= SEQUENCE { wfSmdsSwCurUsageDelete INTEGER, wfSmdsSwCurUsageSni INTEGER, wfSmdsSwCurUsageDestAddr OCTET STRING, wfSmdsSwCurUsageSrcAddr OCTET STRING, wfSmdsSwCurUsageGrpIndAddr OCTET STRING, wfSmdsSwCurUsageNumL3Pdu Counter, wfSmdsSwCurUsageNumOctet Counter, wfSmdsSwCurUsageToBeDeleted INTEGER } wfSmdsSwCurUsageDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS obsolete DESCRIPTION "Indication to delete this current usage entry." DEFVAL { created } ::= { wfSmdsSwCurUsageEntry 1 } wfSmdsSwCurUsageSni OBJECT-TYPE SYNTAX INTEGER(1..65535) ACCESS read-only STATUS mandatory DESCRIPTION "The SNI number of the interface generating the usage information" ::= { wfSmdsSwCurUsageEntry 2 } wfSmdsSwCurUsageDestAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "The destination address of a SMDS group or individual E.164 address." ::= { wfSmdsSwCurUsageEntry 3 } wfSmdsSwCurUsageSrcAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "The source address of a SMDS individual E.164 address." ::= { wfSmdsSwCurUsageEntry 4 } wfSmdsSwCurUsageGrpIndAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "When the destination address of an L3_PDU is a group address, this attribute is set to one of the E.164 individual addresses that is in the group address and on the destination SNI." ::= { wfSmdsSwCurUsageEntry 5 } wfSmdsSwCurUsageNumL3Pdu OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This number represents the number of billable L3_PDUs counted by the circuit during the most recent collection interval." ::= { wfSmdsSwCurUsageEntry 6 } wfSmdsSwCurUsageNumOctet OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This number represents the number of billable octets counted by the circuit during the most recent collection interval." ::= { wfSmdsSwCurUsageEntry 7 } wfSmdsSwCurUsageToBeDeleted OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indication to billing to delete this current usage entry." DEFVAL { created } ::= { wfSmdsSwCurUsageEntry 8 } wfSmdsSwUsage OBJECT IDENTIFIER ::= { wfSmdsSwGroup 9 } wfSmdsSwUsageEnable OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable SMDS_SW billing." DEFVAL { enabled } ::= { wfSmdsSwUsage 1 } wfSmdsSwUsageVolume OBJECT-TYPE SYNTAX INTEGER(0..14) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the file system volume number to which the billing usage data files will be written. The volume number corresponds to the slot number on which the volume resides. Note: Value 0 has the special meaning that no 'Store' and 'Flush' operations will take place. This translates to no Billing data will be written to the local file system. 'Update' operations will still be performed on each local slot. Full Billing statistics will still be available in the wfSmdsSwUsageTable MIB." ::= { wfSmdsSwUsage 2 } wfSmdsSwUsageVolumeBackup OBJECT-TYPE SYNTAX INTEGER(0..14) ACCESS read-write STATUS mandatory DESCRIPTION "Indicates the backup volume if wfSmdsSwUsageVolume becomes inoperative. Note: This feature is not implemented in this release." ::= { wfSmdsSwUsage 3 } wfSmdsSwUsageDirectory OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The name of the directory where the billing usage data files are stored. " ::= { wfSmdsSwUsage 4 } wfSmdsSwUsageFilePrefix OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "The base name of billing usage data files." ::= { wfSmdsSwUsage 5 } wfSmdsSwUsageTimerInterval OBJECT-TYPE SYNTAX INTEGER(1..60) ACCESS read-write STATUS mandatory DESCRIPTION "This number determines the timer interval (number of seconds) unit for the Billing process to perform its various timer driven tasks. i.e. updating billing usage data, writing billing usage data to file system and file system management activities." DEFVAL { 1 } ::= { wfSmdsSwUsage 6 } wfSmdsSwUsageUpdateInterval OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This number specifies the interval (number of minutes) for the Billing process to collect and update billing usage data in the wfSmdsSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfSmdsSwUsageTimerInterval. " DEFVAL { 10 } ::= { wfSmdsSwUsage 7 } wfSmdsSwUsageStoreInterval OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This number specifies the interval (number of minutes) for the Billing process to write billing usage data on to the file system from the wfSmdsSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfSmdsSwUsageTimerInterval. " DEFVAL { 10 } ::= { wfSmdsSwUsage 8 } wfSmdsSwUsageFlushInterval OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This number specifies the interval (number of minutes) for the Billing process to write billing usage data on to the file system from the wfSmdsSwUsage MIB followed by zeroing the wfSmdsSwUsage MIB. Note: When converted to seconds, this must be a multiple of wfSmdsSwUsageTimerInterval. " DEFVAL { 60 } ::= { wfSmdsSwUsage 9 } wfSmdsSwUsageCleanupInterval OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-write STATUS mandatory DESCRIPTION "This is the interval (number of minutes) for the Billing process to check and delete old billing usage data files. Note: When converted to seconds, this must be a multilple of wfSmdsSwUsageTimerInterval. " DEFVAL { 60 } ::= { wfSmdsSwUsage 10 } wfSmdsSwUsageLocalTimeZone OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates local time zone of the switch" ::= { wfSmdsSwUsage 11 } wfSmdsSwUsageUpdateTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of last wfSmdsSwUsageUpdateInterval timer expiration or the starting time of the current wfSmdsSwUsageUpdateInterval. This value is number of seconds since midnight Jan 1, 1976 (GMT). " ::= { wfSmdsSwUsage 12 } wfSmdsSwUsageStoreTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of last wfSmdsSwUsageStoreInterval timer expiration or the starting time of the current wfSmdsSwUsageStoreInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT). " ::= { wfSmdsSwUsage 13 } wfSmdsSwUsageFlushTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of last wfSmdsSwUsageFlushInterval timer expiration or the starting time of the current wfSmdsSwUsageFlushInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT). " ::= { wfSmdsSwUsage 14 } wfSmdsSwUsageCleanupTimeStamp OBJECT-TYPE SYNTAX TimeTicks ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of last wfSmdsSwUsageCleanupInterval timer expiration or the starting time of the current wfSmdsSwUsageCleanupInterval. This value is number of seconds since midnight Jan. 1, 1976 (GMT). " ::= { wfSmdsSwUsage 15 } wfSmdsSwUsageUpdateData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute to a non-zero value will cause an immediate updating of the billing usage data. Once activated, this attribute should be reset to zero to allow subsequent activations. " ::= { wfSmdsSwUsage 16 } wfSmdsSwUsageStoreData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute to a non-zero value will cause an immediate updating and writing of the billing usage data. Once activated, this attribute should be reset to zero to allow subsequent activations. " ::= { wfSmdsSwUsage 17 } wfSmdsSwUsageFlushData OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute to a non-zero value will cause an immediate updating and writing of the billing usage data and followed by zeroing the wfSmdsSwBillingUsage MIB. Once activated, this attribute should be reset to zero to allow subsequent activations. " ::= { wfSmdsSwUsage 18 } wfSmdsSwUsageFileCleanup OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Setting this attribute to a non-zero value will cause an immediate checking and deleting old billing usage data files. Once activated, this attribute should be reset to zero to allow subsequent activations. " ::= { wfSmdsSwUsage 19 } wfSmdsSwUsageState OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), init(3), notpresent(4) } ACCESS read-only STATUS mandatory DESCRIPTION "current state of SMDS_SW billing." DEFVAL { notpresent } ::= { wfSmdsSwUsage 20 } wfSmdsSwUsageCurVolume OBJECT-TYPE SYNTAX INTEGER(0..14) ACCESS read-only STATUS mandatory DESCRIPTION "current file system volume number used. This number is the same as wfSmdsSwUsageVolume except when the user sets wfSmdsSwUsageVolume to an invalid number." ::= { wfSmdsSwUsage 21 } wfSmdsSwUsageCurVolumeBackup OBJECT-TYPE SYNTAX INTEGER(0..14) ACCESS read-only STATUS mandatory DESCRIPTION "curent backup file system volume number used. This number is the same as wfSmdsSwUsageVolumeBackUp except when the user sets wfSmdsSwUsageVolume to an invalid number. Note: This feature is not implemented in this release." ::= { wfSmdsSwUsage 22 } wfSmdsSwUsageCurDirectory OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "current directory name used. This number is the same as wfSmdsSwUsageDirectory except when the user sets wfSmdsSwUsageDirectory to an invalid name." ::= { wfSmdsSwUsage 23 } wfSmdsSwUsageCurFilePrefix OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "current base file name used. This number is the same as wfSmdsSwUsageFilePrefix except when the user sets wfSmdsSwUsageFilePrefix to an invalid name." ::= { wfSmdsSwUsage 24 } wfSmdsSwUsageCurTimerInterval OBJECT-TYPE SYNTAX INTEGER(1..60) ACCESS read-only STATUS mandatory DESCRIPTION "current timer interval number used. This number is the same as wfSmdsSwUsageTimerInterval except when the user sets wfSmdsSwUsageTimerInterval to an invalid value." DEFVAL { 1 } ::= { wfSmdsSwUsage 25 } wfSmdsSwUsageCurUpdateInterval OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "current update interval number used. This number is the same as wfSmdsSwUsageUpdateInterval except when the user sets wfSmdsSwUsageUpdateInterval to an invalid value." DEFVAL { 10 } ::= { wfSmdsSwUsage 26 } wfSmdsSwUsageCurStoreInterval OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "current store timer interval number used. This number is the same as wfSmdsSwUsageStoreInterval except when the user sets wfSmdsSwUsageStoreInterval to an invalid value." DEFVAL { 10 } ::= { wfSmdsSwUsage 27 } wfSmdsSwUsageCurFlushInterval OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "current flush timer interval number used. This number is the same as wfSmdsSwUsageFlushInterval except when the user sets wfSmdsSwUsageFlushInterval to an invalid value." DEFVAL { 60 } ::= { wfSmdsSwUsage 28 } wfSmdsSwUsageCurCleanupInterval OBJECT-TYPE SYNTAX INTEGER(1..2147483647) ACCESS read-only STATUS mandatory DESCRIPTION "current file cleanup timer interval number used. This number is the same as wfSmdsSwUsageCleanupInterval except when the user sets wfSmdsSwUsageCleanupInterval to an invalid value." DEFVAL { 60 } ::= { wfSmdsSwUsage 29 } wfSmdsSwUsageDebug OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable/Disable printing of debug edl (trap) messages. NOTE: Do not enable this attribute in operational enviornment as it will likely flood the logging facility. This attribute is reserved for specialized debugging in a controlled lab enviornment." DEFVAL { disabled } ::= { wfSmdsSwUsage 30 } wfSmdsSwUsageCurDebug OBJECT-TYPE SYNTAX INTEGER { enabled(1), disabled(2) } ACCESS read-only STATUS mandatory DESCRIPTION "current debug value used. This value is the same as wfSmdsSwUsageDebug except when the user sets wfSmdsSwUsageDeubg to an invalid value." DEFVAL { disabled } ::= { wfSmdsSwUsage 31 } wfSmdsSwUsageSwitchId OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "switch id used in the billing usage data file." ::= { wfSmdsSwUsage 32 } wfSmdsSwUsageNumEntries OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "number of entries in wfSmdsSwUsageTable" ::= { wfSmdsSwUsage 33 } wfSmdsSwUsageTable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwUsageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Billing Usage Table." ::= { wfSmdsSwGroup 10 } wfSmdsSwUsageEntry OBJECT-TYPE SYNTAX WfSmdsSwUsageEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters for Billing Usage." INDEX { wfSmdsSwUsageSni, wfSmdsSwUsageDestAddr, wfSmdsSwUsageSrcAddr } ::= { wfSmdsSwUsageTable 1 } WfSmdsSwUsageEntry ::= SEQUENCE { wfSmdsSwUsageDelete INTEGER, wfSmdsSwUsageSni INTEGER, wfSmdsSwUsageDestAddr OCTET STRING, wfSmdsSwUsageSrcAddr OCTET STRING, wfSmdsSwUsageStartTimeStampHigh INTEGER, wfSmdsSwUsageStartTimeStampLow INTEGER, wfSmdsSwUsageEndTimeStampHigh INTEGER, wfSmdsSwUsageEndTimeStampLow INTEGER, wfSmdsSwUsageSentL3PduHigh INTEGER, wfSmdsSwUsageSentL3PduLow INTEGER, wfSmdsSwUsageSentOctetHigh INTEGER, wfSmdsSwUsageSentOctetLow INTEGER, wfSmdsSwUsageLastL3PduHigh INTEGER, wfSmdsSwUsageLastL3PduLow INTEGER, wfSmdsSwUsageLastOctetHigh INTEGER, wfSmdsSwUsageLastOctetLow INTEGER, wfSmdsSwUsageGrpIndAddr OCTET STRING } wfSmdsSwUsageDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-only STATUS mandatory DESCRIPTION "Indicates status of this entry. SMDS_SW_USAGE_CREATED is the normal case. SMDS_SW_USAGE_DELETED means this billing instance will be deleted at the end of the next wfSmdsSwUsageFlush period after this billing record is written out to the file system." DEFVAL { created } ::= { wfSmdsSwUsageEntry 1 } wfSmdsSwUsageSni OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The circuit number of the interface generating the usage information" ::= { wfSmdsSwUsageEntry 2 } wfSmdsSwUsageDestAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "Instance identifier; the destination address of an L3_PDU. The SMDS Switch collects usage data based on the destination/source address pair." ::= { wfSmdsSwUsageEntry 3 } wfSmdsSwUsageSrcAddr OBJECT-TYPE SYNTAX OCTET STRING (SIZE (8)) ACCESS read-only STATUS mandatory DESCRIPTION "Instance identifier; the source address of an L3_PDU. The SMDS Switch collects usage data based on the destination/source address pair." ::= { wfSmdsSwUsageEntry 4 } wfSmdsSwUsageStartTimeStampHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the starting time (the high 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT)." ::= { wfSmdsSwUsageEntry 5 } wfSmdsSwUsageStartTimeStampLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the starting time (the low 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT)." ::= { wfSmdsSwUsageEntry 6 } wfSmdsSwUsageEndTimeStampHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the ending time (the high 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT)." ::= { wfSmdsSwUsageEntry 7 } wfSmdsSwUsageEndTimeStampLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Time stamp of the ending time (the low 32 bits) of last billing usage interval. This value is the number of 1/100th seconds since midnight Jan 1, 1976 (GMT)." ::= { wfSmdsSwUsageEntry 8 } wfSmdsSwUsageSentL3PduHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number (the high 32 bits) of L3_PDUs sent to the CPE between wfSmdsSwUsageStartTimeStamp and wfSmdsSwUsageEndTimeStamp." ::= { wfSmdsSwUsageEntry 9 } wfSmdsSwUsageSentL3PduLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number (the low 32 bits) of L3_PDUs sent to the CPE between wfSmdsSwUsageStartTimeStamp and wfSmdsSwUsageEndTimeStamp." ::= { wfSmdsSwUsageEntry 10 } wfSmdsSwUsageSentOctetHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number (the high 32 bits) of octets sent to the CPE between wfSmdsSwUsageStartTimeStamp and wfSmdsSwUsageEndTimeStamp." ::= { wfSmdsSwUsageEntry 11 } wfSmdsSwUsageSentOctetLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number (the low 32 bits) of octets sent to the CPE between wfSmdsSwUsageStartTimeStamp and wfSmdsSwUsageEndTimeStamp." ::= { wfSmdsSwUsageEntry 12 } wfSmdsSwUsageLastL3PduHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The (high 32 bits) value of wfSmdsSwCurUsageNumL3Pdu value at wfSmdsSwUsageEndTimeStamp. Note: Since wfSmdsSwCurUsageNumL3Pdu is a 32-bit COUNTER, this is really a counter keeping track of number of times wfSmdsSwCurUsageNumL3Pdu has wrapped around." ::= { wfSmdsSwUsageEntry 13 } wfSmdsSwUsageLastL3PduLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The (low 32 bits) value of wfSmdsSwCurUsageNumL3Pdu value at wfSmdsSwUsageEndTimeStamp." ::= { wfSmdsSwUsageEntry 14 } wfSmdsSwUsageLastOctetHigh OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The (high 32 bits) value of wfSmdsSwCurUsageNumOctets value at wfSmdsSwUsageEndTimeStamp. Note: Since wfSmdsSwCurUsageNumOctets is a 32-bit COUNTER, this is really a counter keeping track of number of times wfSmdsSwCurUsageNumOctets has wrapped around." ::= { wfSmdsSwUsageEntry 15 } wfSmdsSwUsageLastOctetLow OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The (low 32 bits) value of wfSmdsSwCurUsageNumOctets value at wfSmdsSwUsageEndTimeStamp." ::= { wfSmdsSwUsageEntry 16 } wfSmdsSwUsageGrpIndAddr OBJECT-TYPE SYNTAX OCTET STRING ACCESS read-only STATUS mandatory DESCRIPTION "When the destination address of an L3_PDU is a group address, this attribute is set to one of the E.164 individual addresses that is in the group address and on the destination SNI." ::= { wfSmdsSwUsageEntry 17 } wfSmdsSwSsiSniTable OBJECT-TYPE SYNTAX SEQUENCE OF WfSmdsSwSsiSniEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The Parameters for the SSI/SNI Object. This object associates SNI's with SSI's for Bellcore TR-TSV-001239 compliance." ::= { wfSmdsSwGroup 11 } wfSmdsSwSsiSniEntry OBJECT-TYPE SYNTAX WfSmdsSwSsiSniEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "The parameters for a particular SSI/SNI." INDEX { wfSmdsSwSsiSniSSI, wfSmdsSwSsiSniSNI } ::= { wfSmdsSwSsiSniTable 1 } WfSmdsSwSsiSniEntry ::= SEQUENCE { wfSmdsSwSsiSniDelete INTEGER, wfSmdsSwSsiSniSSI INTEGER, wfSmdsSwSsiSniSNI INTEGER } wfSmdsSwSsiSniDelete OBJECT-TYPE SYNTAX INTEGER { created(1), deleted(2) } ACCESS read-write STATUS mandatory DESCRIPTION "Indication to delete this SSI/SNI entry." DEFVAL { created } ::= { wfSmdsSwSsiSniEntry 1 } wfSmdsSwSsiSniSSI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An SSI." ::= { wfSmdsSwSsiSniEntry 2 } wfSmdsSwSsiSniSNI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "An SNI." ::= { wfSmdsSwSsiSniEntry 3 } END -- Wellfleet-SWSMDS-MIB