The SNMP protocol is used to for conveying information and commands between agents and managing entities. SNMP uses the User Datagram Protocol (UDP) as the transport protocol for passing data between managers and agents. The reasons for using UDP for SNMP are, firstly it has low overheads in comparison to TCP, which uses a 3-way hand shake for connection. Secondly, in congested networks, SNMP over TCP is a bad idea because TCP in order to maintain reliability will flood the network with retransmissions.

Management information (MIB) is represented as a collection of managed objects. These objects together form a virtual information base called MIB. An agent may implement many MIBs, but all agents must implement a particular MIB called MIB-II [16]. This standard defines variables for things such as interface statistics (interface speeds, MTU, octets sent, octets received, etc.) as well as various other things pertaining to the system itself (system location, system contact, etc.). The main goal of MIB-II is to provide general TCP/IP management information.

Use ActiveXperts Network Monitor 2019 to import vendor-specific MIB files, inclusing Wellfleet-TELNET-MIB.


Vendor: Wellfleet
Mib: Wellfleet-TELNET-MIB  [download]  [view objects]
Tool: ActiveXperts Network Monitor 2019 [download]    (ships with advanced SNMP/MIB tools)
Wellfleet-TELNET-MIB DEFINITIONS ::= BEGIN

-- Created by mdl2asn version 3.1
-- Creation date: Wed Aug 30 16:49:25 EDT 1995


    IMPORTS

      Counter, Gauge
        FROM RFC1155-SMI
      OBJECT-TYPE
        FROM RFC-1212
      DisplayString
        FROM RFC1213-MIB
      wfTelnetGroup
        FROM Wellfleet-COMMON-MIB;


    wfTelnet	OBJECT IDENTIFIER ::= { wfTelnetGroup 1 }

    wfTelnetDelete OBJECT-TYPE
        SYNTAX	INTEGER {
    		    created(1),
    		    deleted(2)
    		}
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Create/Delete parameter. Default is created.
                Users perform a set operation on this
                object in order to create/delete TELNET."
        DEFVAL	{ created }
        ::= { wfTelnet 1 }

    wfTelnetDisable OBJECT-TYPE
        SYNTAX	INTEGER {
    		    enabled(1),
    		    disabled(2)
    		}
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Enables or Disables TELNET Subsystem"
        DEFVAL	{ enabled }
        ::= { wfTelnet 2 }

    wfTelnetLinesPerScreen OBJECT-TYPE
        SYNTAX	INTEGER
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Number of lines which can be displayed in one screen on the Telnet
                Technician Interface console.
                (Default value if NAWS option not negotiated)"
        DEFVAL	{ 24 }
        ::= { wfTelnet 3 }

    wfTelnetMoreDisable OBJECT-TYPE
        SYNTAX	INTEGER {
    		    enabled(1),
    		    disabled(2)
    		}
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Enable the 'more' feature on the Telnet Technician Interface console"
        DEFVAL	{ enabled }
        ::= { wfTelnet 4 }

    wfTelnetPrompt OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Character string which will be used as the system prompt on
                the Telnet Technician Interface console"
        ::= { wfTelnet 5 }

    wfTelnetLoginTimeOut OBJECT-TYPE
        SYNTAX	INTEGER(1..99)
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Time out in minutes to Disconnect when at the login prompt"
        DEFVAL	{ 1 }
        ::= { wfTelnet 6 }

    wfTelnetPasswordTimeOut OBJECT-TYPE
        SYNTAX	INTEGER(1..99)
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Timout in minutes on Password entry"
        DEFVAL	{ 1 }
        ::= { wfTelnet 7 }

    wfTelnetCommandTimeOut OBJECT-TYPE
        SYNTAX	INTEGER(1..99)
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Time out in minutes to Disconnect when at the command prompt"
        DEFVAL	{ 15 }
        ::= { wfTelnet 8 }

    wfTelnetLoginRetries OBJECT-TYPE
        SYNTAX	INTEGER(1..99)
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Limit # of login attempts then Disconnect"
        DEFVAL	{ 3 }
        ::= { wfTelnet 9 }

    wfTelnetTotalLogins OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "Total number of Telnet TI login attempts"
        ::= { wfTelnet 10 }

    wfTelnetUserLoginErrors OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "Total number of FAILED User login attempts"
        ::= { wfTelnet 11 }

    wfTelnetManagerLoginErrors OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "Total number of FAILED Manager login attempts"
        ::= { wfTelnet 12 }

    wfTelnetOtherLoginErrors OBJECT-TYPE
        SYNTAX	Counter
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "Total number of FAILED Other login attempts"
        ::= { wfTelnet 13 }

    wfTelnetActiveSessions OBJECT-TYPE
        SYNTAX	Gauge
        ACCESS	read-only
        STATUS	mandatory
        DESCRIPTION
                "Total number of Telnet TI Sessions"
        ::= { wfTelnet 14 }

    wfTelnetDiagnosticReport OBJECT-TYPE
        SYNTAX	INTEGER {
    		    enabled(1),
    		    disabled(2)
    		}
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Diagnostic Flag: report prints the options
                information, plus some additional information about
                what processing is  going  on"
        DEFVAL	{ disabled }
        ::= { wfTelnet 15 }

    wfTelnetDiagnosticExercise OBJECT-TYPE
        SYNTAX	INTEGER {
    		    enabled(1),
    		    disabled(2)
    		}
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Diagnostic Flag: Not implemented yet."
        DEFVAL	{ disabled }
        ::= { wfTelnet 16 }

    wfTelnetDiagnosticNetworkData OBJECT-TYPE
        SYNTAX	INTEGER {
    		    enabled(1),
    		    disabled(2)
    		}
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Diagnostic Flag: NETDATA displays the data
                stream received by telnetd"
        DEFVAL	{ disabled }
        ::= { wfTelnet 17 }

    wfTelnetDiagnosticPtyData OBJECT-TYPE
        SYNTAX	INTEGER {
    		    enabled(1),
    		    disabled(2)
    		}
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Diagnostic Flag: PTYDATA displays data written to the pty"
        DEFVAL	{ disabled }
        ::= { wfTelnet 18 }

    wfTelnetDiagnosticOptions OBJECT-TYPE
        SYNTAX	INTEGER {
    		    enabled(1),
    		    disabled(2)
    		}
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "Diagnostic Flag: OPTIONS prints information about
                the negotiation of TELNET options"
        DEFVAL	{ disabled }
        ::= { wfTelnet 19 }

    wfTelnetInitialSearchPath OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-write
        STATUS	obsolete
        DESCRIPTION
                "Example:  'A:;1:;2:' or '2:;4:6:;9:"
        ::= { wfTelnet 20 }

    wfTelnetManagerAutoScript OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "for each login."
        ::= { wfTelnet 21 }

    wfTelnetUserAutoScript OBJECT-TYPE
        SYNTAX	DisplayString
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "for each login."
        ::= { wfTelnet 22 }

    wfTelnetUserAbortLogoutDisable OBJECT-TYPE
        SYNTAX	INTEGER {
    		    enabled(1),
    		    disabled(2)
    		}
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "a USER from escaping out of the User Autoscript"
        DEFVAL	{ disabled }
        ::= { wfTelnet 23 }

    wfTelnetHistoryDepth OBJECT-TYPE
        SYNTAX	INTEGER(1..40)
        ACCESS	read-write
        STATUS	mandatory
        DESCRIPTION
                "TI command history table size"
        DEFVAL	{ 20 }
        ::= { wfTelnet 24 }

    wfTelnetReverseEnable OBJECT-TYPE
        SYNTAX  INTEGER {
                   enabled(1),
                   disabled(2)
                }
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Reverse Telnet enabled"
        DEFVAL  { disabled }
        ::= { wfTelnet 25 }
 
     wfTelnetReversePort OBJECT-TYPE
        SYNTAX  INTEGER(1..2)
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
                "Console port to use for reverse telnet"
        DEFVAL  { 1 }
        ::= { wfTelnet 26 }


    END  -- Wellfleet-TELNET-MIB